Code
Name
0469
Image file open error
046A
Image lock/unlock error
0532
Polygon error 1
0534
Laser power error 1
0536
Analog power supply error 1
0537
Start-point detection error 1
0538
Leading-edge detection error 1
0549
End-of-screen error
0701
Standard LAN initial setup error
0702
LAN board option disabled
0703
System file setup value error
0704
No valid IDT
009-051-06
009-051-04
04.20.2001 FM3006
05.31.99 FM2460
5
6
Significance/Occurrence Condition
During reading, an attempt to open the image file for write
retry to the hard disk fails.
During reoutput, an attempt to lock or unlock the image fails.
With polygon status check after initial laser power-ON,
an error is detected.
With initial laser power status check, an error is detected.
Analog power supply error is detected in the PMT08A board. • Check and replace the PMT08A board.
With initial start-point detection status check, an error is
detected.
With initial leading-edge detection status check, an error is
detected.
No end-of-screen interrupt occurs during read.
Initialization of the standard LAN fails.
The CPU90F (LAN board) cannot be used.
An error (irset.cfg) occurs during system file setup value
check.
A valid IDT is not set (equip/hosts).
CR-IR341 Service Manual
Detail: Denotes the detail information format.
Probable Cause/Remedy
Faulty HDD, MTH board, etc.
Faulty HDD, MTH board, etc.
Check and replace the polygonal mirror assembly.
Check and replace the light source section.
• Check and replace the power supply.
Check and replace the SYN08A board.
Check and replace the IP leading-edge sensor
(SED08A).
Check and replace the SCN08A board, polygonal mirror
assembly, light source section, and SYN08A board.
• The software is faulty.
• The CPU90E board is faulty.
• The LAN board is not inserted.
• The LAN board is faulty.
The setup value for ILA in the system file is out of
range.
• A host name for the IDT is not described in equip.
• A host address for the IDT is not set.
MT - 12
Refer to
Detail
E-4
E-6
E-3
E-3
E-3
E-3
E-3
MD - 85
E-3
H
H
F
F