FujiFilm CR-IR341 Service Manual page 345

Fuji computed radiography
Table of Contents

Advertisement

C
1
2
ONTENTS
03A8 Out-Of-Spec Initialization IP Size/13A8 Out-Of-Spec IP Size
Cause
03A8: Measurement is made on the length of the IP during IP feed, but the result is detected
as out-of-spec.
13A8: Measurement is made on the length of the remaining IP during initialization, but the
result is detected as out-of-spec.
Supplementary Explanation
03A8:
Each motor is activated during initialization, and each sensor is used to detect any
remaining IP left in the machine.
The remaining IP in the machine is conveyed, and IP length measurement is per-
formed by SC1.
The size of the IP is determined according to the ON/OFF status of SA4, 8, 12, and 16
(mammo/ST sensor), and SB4 (inch/metric sensor), as well as the time taken for the IP
to pass over SC1.
This error occurs when the size of the remaining IP is out of spec as a result of the
above operation.
13A8:
IP length measurement is performed by SC1 during IP conveyance.
The size of the IP is determined according to the ON/OFF status of SA4, 8, 12, and 16
(mammo/ST sensor), and SB4 (inch/metric sensor), as well as the time taken for the IP
to pass over SC1.
This error occurs when the size of the IP conveyed is out of spec as a result of the
above operation.
Sensor related
Error-related I/O locations
Error-related system block diagram
AC IN
CN5
DC OUT2
JPS-1
DC OUT3
009-051-04
05.31.99 FM2460
3
4
5
6
ON: Close, OFF: Open
MC1
IP transport motor
SC1 Before-BCR IP sensor
SNS08A
CNF1
CN
CN8
CN13
CNC1
CN4
CN5
DRV03D
CN3
CN2
CNZ7
CN2
CN3
CN5
CNMD3
DRV08A
CNC2
CN1
CN8
CNMC1
CR-IR341 Service Manual
SOLA4
MD3 IP transport motor
SA4
CNA1
SA4
SA8
SA8
SC1
SA12
SA12
SA16
SA16
MD3
MC1
FR1H0005.EPS
MT - 76
FR1H0004.EPS
MT - 76