13A1 Cassette Setting Error
Cause
The cassette is inserted into the cassette set unit, but SA3, 7, 11 and 15 do not turn
OFF.
Supplementary explanation
When the cassette is inserted into the cassette set unit, either SA2, 65, 10 or 15
(relevant shelf) is turned ON.
To hold the cassette inserted, SOLA1-4 are turned OFF.
As SOLA1-4 turn OFF, the hold pin is raised, so that SA3, 7, 11, and 15 turn ON,
thereby detecting the hold.
This error occurs when SOLA1-4 turn OFF but SA3, 7, 11, and 15 fail to turn ON so
that the cassette hold cannot be detected during the above operation.
Sensor related
Error-related I/O locations
Error-related system block diagram
AC IN
DC OUT2
JPS-1
DC OUT3
009-051-04
05.31.99 FM2460
3
4
5
6
ON: Close, OFF: Open
SOLA1
SOLA2
SOLA3
SOLA4
SOLF1
SNS08A
CN
CN6
CN13
CN4
DRV03D
CN3
CNA3
CN3
CN4
DRV08A
CN1
CR-IR341 Service Manual
SA3, 7, 11, 15
Cassette hold sensor
SOLA1—4 ON :SA3, 7, 11, 15 OPEN
SOLA1—4 OFF:SA3, 7, 11, 15 CLOSE
Cassette hold solenoid
SF3
CNA2
SOLA1
SOLA2
SOLA3
SOLA4
FR1H0105.EPS
Hold pin
SOLA1—4
Cassette hold solenoid