FujiFilm CR-IR341 Service Manual page 611

Fuji computed radiography
Table of Contents

Advertisement

C
1
2
ONTENTS
8.7
Replacing IP Transport Motor (MD3)
Replacement
(1) Remove the following cover.
Lower rear cover
"3. Removing and Reinstalling Covers"
(2) Cut the cable tie.
(3) Disconnect CNMD3.
(4) Remove MD3 together with the bracket.
(5) Remove MD3 from the bracket.
(6) Remove the timing belt wheel from MD3.
(7) Install to a new MD3 the timing belt wheel that was removed at step (6).
(8) For reinstallation, reverse the removal steps.
Put the timing belt onto the timing belt wheel of MD3 and then secure MD3 in place.
009-051-04
05.31.99 FM2460
3
4
5
6
(6)
Timing belt wheel
CR-IR341 Service Manual
7
8
9
10
(4)
Bracket
BR M4x8, x3
(5)
MD3
Pan head screw M3x10, x3
(3)
CNMD3
FR1H1782.EPS