(4) Verify that the PMT08A board socket section is in close contact with the light-collecting
guide.
If anything abnormal is found, push in the PMT08A board assembly while holding the
light-collecting guide, and adjust the position of the sockets of the PMT08A board and
light-collecting guide as appropriate.
CAUTIONS
• Wear gloves when handling the light-collecting guide assembly. If it is handled with
bare hands, the light-collecting guide assembly may be soiled or damaged.
• Wear a mask to prevent saliva from sputtering around on the light-collecting guide.
Parallel
(5) Reinstall the light-collecting guide assembly.
" Reinstallation"
009-051-04
05.31.99 FM2460
3
4
5
6
Light-collecting guide assembly
Socket
PMT08A board
OK
CR-IR341 Service Manual
7
8
9
10
Not parallel
MC - 173
NG
FR1H1798.EPS
MC - 173