FujiFilm CR-IR341 Service Manual page 367

Fuji computed radiography
Table of Contents

Advertisement

C
1
2
ONTENTS
03BF Side-Positioning Grip Operation Error
Cause
SD2 does not turn ON during the side-positioning grip HP detection.
Supplementary explanation
During initialization, MD2 is driven to turn ON SD2, thereby detecting the HP.
When MD2 is driven, the actuator causes SD2 to detect ON/OFF.
When SD2 is ON during initialization, MD2 is driven to turn OFF SD2. The HP is
detected by driving MD2 again to turn ON SD2.
When SD2 is OFF during initialization, MD2 is driven to turn ON SD2.
This error occurs when SD2 fails to turn ON, or when it does not transition from ON to
OFF to ON, during the above operation.
Reference: If any trouble occurs on MD2 prior to side-positioning operation, "03C1
Sensor related
Error-related I/O locations
SC2
Error-related system block diagram
AC IN
DC OUT2
JPS-1
DC OUT3
009-051-04
05.31.99 FM2460
3
4
5
6
Reading Conveyance Error" occurs. After that, during initialization upon
power-ON again, 03BF error occurs.
ON: Close, OFF: Open
SC1
SD2
Grip release motor
SNS08A
CN
CN9
CN13
CN4
DRV03D
CN3
CN3
CN12
DRV08A
CN1
CR-IR341 Service Manual
CNZ2
CND1
CNZ6
MD2
CNMD2
FR1H0039.EPS
MT - 98
SOLA4
MD2
Grip release HP sensor
FR1H0038.EPS
MT - 98