FujiFilm CR-IR341 Service Manual page 739

Fuji computed radiography
Table of Contents

Advertisement

C
11
12
ONTENTS
Checking and Replacing Shock Absorber of Branch Path Changeover Guide
(1) Remove the erasure conveyor.
"12.2 Removing and Reinstalling Erasure Conveyor"
(2) Remove the guide plate.
(3) Check if the shock absorber is not peeled or frayed.
If it is peeled or frayed, replace the whole guide plate to which the shock absorber is
attached.
If it is not peeled or frayed, reinstall the guide plate in reverse order of removal.
(3)
Shock absorber-attached branch
(4) Remove the spring.
(5) Remove the two screws that retain the stopper support, and remove the stopper
support.
(6) Remove SF1 without disconnecting the connector.
Pan head screw
M3x10, x2
Branch path changeover
009-051-04
05.31.99 FM2460
13
14
15
16
path changeover guide
(2)
Guide plate
BR M3x6, x4
(6)
SF1
guide assembly
CR-IR341 Service Manual
Arm
(4)
Spring
(5)
Stopper support
BR M4x8, x2
FR1H1629.EPS
MC - 248
Erasure conveyor
FR1H1628.EPS
MC - 248