7.5
Subscanning Unit
Driving Shaft Roller/Driven Shaft Roller
The IP conveyed to the driven shaft of the scanner unit is conveyed by the driving of FFM
(MZ1) and operation of the driven shaft roller and driving shaft roller to initiate reading.
To drive the upper driven shaft roller and upper driving shaft roller, their respective motors
are used; as the cam attached thereto is rotated, the upper driven shaft roller or upper
driving shaft roller is operated (up and down). The rotation of the cam facilitates smooth up/
down operation of the upper rollers, thereby preventing uneven IP fluctuations.
Driven Shaft Grip
For the IP conveyed to the driven shaft, in order to initiate gripping of the driven shaft roller,
MZ3 is activated to cause the driven shaft roller to move down (descend), thereby gripping
the IP. The descend position is detected as the sensor SZ3 becomes CLOSE from the
OPEN status. After gripping of the driven shaft roller is completed, the driving of FFM (MZ1)
is initiated, thereby conveying the IP to the IP leading-edge sensor (SZ1).
After-reading conveyor side
SZ2
009-051-04
05.31.99 FM2460
3
4
5
6
Light-collecting mirror
FF shaft
Subscanning unit
MZ2
SZ2
Sensor
Cam
arm for SZ2
MZ2
Grip (solid line) : Z2 (OPEN)
Grip release (dotted line) : SZ2 (CLOSE)
MZ2
Sensor arm
MZ3
for SZ2
CR-IR341 Service Manual
7
8
9
10
MD3
Driven shaft
SZ1
Side-positioning
SD3
reference/location of
side-positioning latch
Side-positioning conveyor
MZ3
Sensor arm for SZ3
SZ3
Cam
MZ3
Grip (solid line) : SZ3 (CLOSE)
Grip release (dotted line) : SZ3 (OPEN)
FFM (MZ1)
CCW: reading
Side-positioning
conveyor side
Sensor arm for SZ3
SZ3
FR1H0220.EPS
conveyance
Conveyance
direction
IP