4.10 Replacing Inch/Metric Guides

(1) Remove the shutter assembly.
"4.3 Removing and Reinstalling Shutter Assembly"
(2) Remove the rubber rollers at the stage where the inch/metric guides to be replace are
located.
"4.12 Replacing Rubber Rollers of Cassette Set Unit"
(3) While holding down the mounting bracket, remove the four hex socket head bolts from
the inch/metric guides.
Cassette set unit
(4) Remove the inch/metric guides.
(5) For installation of a new inch/metric guide, reverse the removal steps.
009-051-04
05.31.99 FM2460
3
4
5
6
(3)
Inch-system guide (white guide)
Hex socket head bolt M3x12, x2
Cap M3x10
(3)
Metric-system guide (brown guide)
Hex socket head bolt M3x12, x2
Cap M3x10