(12) Power OFF the machine.
(13) Install the SF4-attached bracket as a whole.
Replacement
(1) Disconnect the connector (SF4).
(2) Remove the SF4-attached bracket as a whole.
(3) Cut the cable tie.
(4) Disconnect the connector (SF4) from the bracket.
(5) Remove SF4 (both on the light emitting and light receiving sides).
(6) Reverse the removal steps to reinstall a new SF4.
(7) Check SF4.
" Checks"
009-051-04
05.31.99 FM2460
13
14
15
16
(3)
Cut cable tie
Erasure conveyor
CR-IR341 Service Manual
(5)
SF4
4
Sems M3x6 x
(1), (4)
Connector
(2)
Bracket
BR M4x8
FR1H1265.EPS