FujiFilm CR-IR341 Service Manual page 217

Fuji computed radiography
Table of Contents

Advertisement

C
1
2
ONTENTS
6.2
Error Handling: Cassette Ejection 2
(1) Overall/General Sequence
In this sequence, an error IP is returned to the
cassette.
The next IP processing is initiated after removal of
the error IP.
Corresponding sequences
Fig. 2.4.3 Feed Suction Conveyance
Fig. 2.4.4
Fig. 2.10.3 Load Suction
Fig. 2.10.4 Load Suction Conveyance
Fig. 4.2.2
Fig. 4.2.3 Load Step Operation (1/3 and 2/3)
Fig. 6.2.1 Error Handling: Cassette Ejection 2
Removal of the cassette
for the error IP is notified
to the user, and after the
cassette removal, an
elevation permission is
issued to start the
processing for the next
IP in the queue.
Cassette ejection 2
If hold release
failure occurs
during cassette
ejection 2, the
system goes
down.
Return to normal routine
009-051-04
05.31.99 FM2460
3
4
5
6
Feed Conveyance
Feed Step Operation (2/3 and 3/3)
Preprocessing: Fig. 2.4.3, Fig. 2.4.4, Fig. 2.10.3,
Fig. 2.10.4, Fig. 4.2.2, and Fig. 4.2.3
START
Error message output
"STOP ALARM
/ UNLOAD CASS."
Alarm disabled
Cassette removed
Cassette hold
release 2
Fig.6.2.2
LEDT2 is turned on
Cassette removal
Is SA1 opened?
N
Y
DELAY TA13
Is SA2 opened?
N
Y
LEDT2 is turned off
LEDT1 is turned on
Elevation permission
is issued
END
CR-IR341 Service Manual
7
8
9
10
Table 6.2.1 Operation Parameters
Symbol
Wait for cassette OUT
TA13
Table 6.2.1a List of I/O Names Used in the Flow and Drawing
I/O name
in flow
SA1
SA2
LEDT1
LEDT2
No matter whether there is
any IP in the machine or
there is any unprocessed
cassette, it is placed in a
queue until an elevation
permission.
Another IP in the machine
proceeds to the load
standby condition.
The unprocessed cassette
enters the feed standby
condition.
The cassette removable
condition is indicated.
Operation performed
by the operator
Instant return of cassette
is supported.
The ready condition is
indicated.
This elevation permission
allows the process to start.
If there is another IP in
the machine,up-down load
load.
If there is any unprocessed
cassette, up-down feed
feed.
MD - 154
Description
I/O name
Topmost
2nd shelf
3rd shelf
shelf
position
position
position
SA1
SA5
SA9
SA2
SA6
SA10
LEDT1
LEDT3
LEDT5
LEDT2
LEDT4
LEDT6
FR1H0441.EPS
MD - 154
Value
0.5 sec
TR1H0094.EPS
4th shelf
position
SA13
SA14
LEDT7
LEDT8
TR1H0095.EPS

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr-ir341pFcr 5000Fcr 5000plus

Table of Contents