10.6 Checking and Replacing Driving-Side Grip Release HP
Sensor (SZ2)
Checks
If anything abnormal is found during checks, replace SZ2.
"2.2 Checking Various Sensors"
NOTE
When monitoring SZ2, insert an Allen wrench into the cam of MZ2 and rotate it clockwise to
check the OPEN/CLOSE status of SZ2.
Replacement
(1) Pull out the scanner unit.
"7. Pulling Out and Pushing In Scanner Unit"
(2) Remove the light-collecting guide assembly.
"10.2 Servicing Light-Collecting Guide"
(3) Remove the after-reading conveyor.
"11.1 Removing and Reinstalling After-Reading Conveyor"
(4) Disconnect the connector (SZ2).
(5) Remove the SZ2 bracket.
(6) Take out SZ2 from the bracket.
(7) Reverse the removal steps to reinstall a new SZ2.
(8) Check SZ2.
" Checks"