FujiFilm CR-IR341 Service Manual page 676

Fuji computed radiography
Table of Contents

Advertisement

1
2
C
ONTENTS
(14) Block the sensor hole of the SED08A board with a piece of cardboard or the like.
Verify that D15 on the SCN08A board is not lit. If D15 is lit, replace the SED08A board.
(15) Remove the piece of cardboard that blocks the sensor hole.
Verify that D15 on the SCN08A board is lit. If D15 is not lit, replace the SED08A board.
Replacement
(1) Pull out the scanner unit.
"7. Pulling Out and Pushing In Scanner Unit"
(2) Remove the light-collecting guide assembly.
"10.2 Servicing Light-Collecting Guide"
(3) Remove the scanning optics unit.
"9.3 Removing and Reinstalling Scanning Optics Unit"
(4) Remove the subscanning unit guide.
"10.15 Replacing Subscanning Unit Guide"
(5) Remove the cable clamp.
(6) Disconnect the connector (SZ1).
(7) Remove SZ1.
(8) Install a new SZ1 by reversing the removal steps.
When installing SZ1, screw it down while pressing it against the front side.
Subscanning unit
009-051-06
009-051-04
04.20.2001 FM3006
05.31.99 FM2460
3
4
5
6
CR-IR341 Service Manual
7
8
9
10
(7)
Top view
(8)
F
R
O
N
T
Positioning direction
MC - 185
SZ1
Screw x2
SZ1
FR1H1313.EPS
MC - 185