FujiFilm CR-IR341 Service Manual page 347

Fuji computed radiography
Table of Contents

Advertisement

C
1
2
ONTENTS
03B1 Feed Conveyance Error
Cause
After the IP, which is removed from the cassette and conveyed to the elevation unit,
passes over SB2, SC1 does not turn ON. Or, SC1 turns ON, but is not turned OFF.
Supplementary explanation
The IP removed from the cassette is conveyed to the up-down IP removal unit by the
driving of MB2 and passes over SB2. (SB2: OFF to ON)
The IP conveyed to the up-down IP removal unit is conveyed to the before-side-
positioning conveyor by the driving of MC1, and passes over SC1. (SC1: OFF to ON)
IP length measurement is performed according to the time taken to pass over SC1,
thereby determining the IP size.
This error occurs when the IP that is conveyed from the cassette fails to pass over
SC1 (SC1 status does not transition from OFF to ON) after it passes over SB2, or
when it does not completely pass over SC1 (SC1 status does not transition from ON to
OFF) during the above operation.
Sensor related
Error-related I/O locations
Error-related system block diagram
AC IN
DC OUT2
JPS-1
DC OUT3
009-051-04
05.31.99 FM2460
3
4
5
6
ON: Close, OFF: Open
SC1
Before-BCR IP sensor
SNS08A
CN
CN13
CN4
DRV03D
CN3
CN3
DRV08A
CN1
CR-IR341 Service Manual
MC1
IP transport motor
CNF1
CNC1
CNZ7
MD3
CNMD3
CNC2
MC1
CNMC1
FR1H0008.EPS
MT - 78
SOLA4
MD3 IP transport motor
FR1H0007.EPS
MT - 78

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr-ir341pFcr 5000Fcr 5000plus

Table of Contents