12.4 4. RESTORE: Reading Various Data
Various setup files are loaded from the floppy disk to the hard disk.
NOTE
Before installing the configuration data that was edited on the PC or the like, make sure that
the software versions for the machine where the data was extracted and the machine where
it is to be installed are the same. If the software versions are different, error may occur
during installation.
1. SCANNER DATA: To Read Scanner Data from FD to HD
(1) Select "1. SCANNER DATA".
The following message appears.
PLEASE SET A FD.
ARE YOU SURE TO COPY SCANNER DATAS TO THE HD ?
1.YES 2.NO (DEFAULT=2) :
Meaning: Put a floppy disk into the floppy disk drive. Are you sure to copy the scanner
(2) Select "1".
Once the data is copied to the hard disk, the following message appears.
XXXXXXXXXX IS COPIED.
Meaning: XXXXXXXXXX is copied.
If the coping ends in error, the following message is displayed.
FILE I/O ERROR. (FILE=XXXXXXXXXX)
XXXXXXXXXX denotes the file name.
The following files are read from the floppy disk to the hard disk.
• SCN_IFMT.DAT
• SCN_POLY.POL
• SCN_SHDG.SHD
009-051-05
11.20.99 FM2638
13
14
15
16
data to the hard disk?
• SCN_INIT.DAT
• SCN_ISEN.DAT