(5) Remove the four screws and one spacer that retain the subscanning unit guide plate.
(6) Slide the right-hand-side grip arm removed at step (4) to remove the subscanning unit
guide plate.
(7) Install a new subscanning unit guide plate in reverse order of removal.
NOTES
• To install the subscanning unit guide plate, loosely tighten the four screws and then
align the guide plate in the arrow directions illustrated below to position it as appro-
priate.
Top view
F
R
O
N
T
• After installing the subscanning unit guide plate, place a rule or the like on the lower
rubber rollers, and rotate the drive shaft to check if the rule is moved, thereby
verifying that the surface of the lower rubber rollers is above the subscanning unit
guide plate (at six locations).
Subscanning unit guide plate
(8) Power ON the machine.
(9) Check image performance.
"3.2 Checking Image" in Preventive Maintenance Volume
009-051-04
05.31.99 FM2460
3
4
5
6
Subscanning unit guide plate
BR M4x8, x3
Drive shaft
Scale
CR-IR341 Service Manual
7
8
9
10
BR M4x12 + Spacer
Lower rubber roller
MC - 203
FR1H1530.EPS
FR1H4018.EPS
MC - 203