(7) Remove the elevation changeover guide, using care to avoid interference with the side
plate of the vertical conveyor and so forth.
Shock absorber-attached
elevation changeover guide
Vertical conveyor
Shock absorber-attached
elevation changeover guide
(8) Install a new elevation changeover guide.
(9) Reinstall both the right and left slide bearings removed at step (6).
(10) From the front side of the machine, reinstall both the right and left E-rings removed at
step (5).
First install the E-ring on the right-hand side of the machine.
(11) Reinstall the arm removed at step (4).
(12) Secure the elevation changeover guide to the arm in place with the single screw
removed at step (3).
(13) Reinstall the spring removed at step (2).