FujiFilm CR-IR341 Service Manual page 431

Fuji computed radiography
Table of Contents

Advertisement

1
2
C
ONTENTS
13E4 Load IP Suction Error
Cause
To return into the cassette the IP that has been load conveyed, PB1 is turned ON to
suck the IP with the suction cups, but SB5 does not turn ON.
Supplementary explanation
The IP that has been erasure conveyed is conveyed through the before-side-position-
ing conveyor to the up-down IP removal unit.
To suck the IP that is conveyed to the IP removal unit, the suction cups are moved
from the load standby position to the load suction position by the driving of MB1.
To suck the IP with the suction cups, PB1 is turned ON.
When the suction of the IP by the suction cups is detected, SB5 turns ON.
This error occurs when SB5 does not turn ON during the above operation.
Sensor related
Error-related I/O locations
Error-related system block diagram
AC IN
DC OUT2
JPS-1
DC OUT3
009-051-04
05.31.99 FM2460
3
4
5
6
ON: Close, OFF: Open
PB1
IP suction
SNS08A
CN
CN13
CN4
DRV03D
CN3
CN3
CNB4
DRV08A
CN1
CR-IR341 Service Manual
SB5
Suction sensor
FR1H0134.EPS
CNB1
CNB2
CNPB1
PB1
FR1H0135.EPS
MT - 162
MT - 162

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr-ir341pFcr 5000Fcr 5000plus

Table of Contents