FujiFilm CR-IR341 Service Manual page 571

Fuji computed radiography
Table of Contents

Advertisement

C
1
2
ONTENTS
Checking and replacing shock absorbers located under IP removal unit
(1) Take out the four shock absorber-attached guides from under the IP removal unit.
(2) Check if the shock absorber is not peeled or frayed.
If it is peeled or frayed, replace the whole guide to which the shock absorber is at-
tached.
(3) Reinstall the shock absorber-attached guides.
Fit the lower portion of the guide into the groove of the lower shaft, and push the upper
portion of the guide against the upper shaft to secure it in place.
Side view
(1)
Pull
(2), (3)
Lower portion of
IP removal unit
Shock absorber-attached guide
009-051-04
05.31.99 FM2460
3
4
5
6
Shaft
CR-IR341 Service Manual
7
8
9
10
IP removal unit
Groove
Shaft
MC - 80
FR1H1428.EPS
MC - 80

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr-ir341pFcr 5000Fcr 5000plus

Table of Contents