FujiFilm CR-IR341 Service Manual page 696

Fuji computed radiography
Table of Contents

Advertisement

C
1
2
ONTENTS
10.17 Replacing and Adjusting Shock-Absorbing Rubbers
When replacing the shock-absorbing rubbers, be sure to replace all the four shock-
absorbing rubbers.
The shock-absorbing rubbers should be removed and installed one by one.
Replacement
On the after-reading conveyor side
(1) Remove the after-reading conveyor.
"11.1 Removing and Reinstalling After-Reading Conveyor"
(2) Remove the three screws and two spacers that retain the shock-absorbing rubber.
(3) While lifting up the subscanning unit slightly, take out the shock-absorbing rubber.
(4) Reinstall the shock-absorbing rubber in reverse order of removal.
(5) Make adjustment after replacement of the shock-absorbing rubber.
" Adjustment"
On the side-positioning conveyor side
(1) Remove the side-positioning conveyor.
"8.1 Removing and Reinstalling Side-Positioning Conveyor"
(2) Remove the three screws and two spacers that retain the shock-absorbing rubber.
(3) While lifting up the subscanning unit slightly, take out the shock-absorbing rubber.
(4) Reinstall the shock-absorbing rubber in reverse order of removal.
(5) Make adjustment after replacement of the shock-absorbing rubber.
" Adjustment"
009-051-05
009-051-06
04.20.2001 FM3006
11.20.99 FM2638
3
4
5
6
Shock-absorbing
Scanner unit
rubber
BR M6x12, x3
Spacer x2
Scanner unit
CR-IR341 Service Manual
7
8
9
10
MC - 205
FR1H1819.EPS
Shock-absorbing
rubber
BR M6x12, x3
Spacer x2
FR1H1820.EPS