FujiFilm CR-IR341 Service Manual page 87

Fuji computed radiography
Table of Contents

Advertisement

C
1
2
ONTENTS
7.3
Before-Side-Positioning Conveyor
IP Length Measurement
The IP conveyed from the up-down IP removal unit is subjected to IP length measurement
by SC1 (IP passage time through SC1) and routed to the side-positioning conveyor.
For IP length measurement, the IP size is classified into eight types according to the length
of the IP, SB4 status during IP feed, and mammo/ST cassette sensor status. If the passage
time through SC1 is 2.9 sec or longer, it is judged as an IP jam.
IP type setting
14" x 17"
14" x 14"
10" x 12"
8" x 10"
18cm x 24cm ST
24cm x 30cmST
18cm x 24cm HR
24cm x 30cm HR
009-051-04
05.31.99 FM2460
3
4
5
6
Length
SC1 passage
x width
time
mm
Sec
430 x 354
0.83—2.9
354 x 354
0.7—0.83
303 x 252
0.57—0.7
201 x 252
—0.57
178 x 238
—0.57
298 x 238
0.57—0.7
178 x 238
—0.57
238 x 298
—0.57
Guide
SOLC1
OFF
SOLC1
SC2
IP path
Before-side-
positioning conveyor
CR-IR341 Service Manual
7
8
9
10
SB4 result
SA4, 8, 12, 16 status
CLOSE
CLOSE
CLOSE
CLOSE
OPEN
OPEN
OPEN
CLOSE
Guide
SOLC1
ON
SC1
IP path
FR1H0212.EPS
MD - 24
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
CLOSE
CLOSE
TR1H0001.EPS
MD - 24