Troubleshooting flow
03A2 Cassette hold release error / 03A3 Degeneration for all shelves
Cause
03A2: SOLA1-4 is turned ON during cassette hold release after occurrence of 13E1-13E5,
but SA3, 7, 11, and 15 do not turn OFF so that the cassette cannot be released.
03A3: Cassette hold release is performed during initialization or during machine operation, but
hold release for all the shelves (SA3, 7, 11, and 15 do not turn OFF) cannot be detected.
Supplementary explanation
Upon initialization or cassette ejection, SOLA1-4 turn ON for releasing the cassette
hold.
When the SOLA1-4 turn ON, the hold pin is withdrawn, so that SA3, 7, 11, and 15 turn
OFF, thereby detecting the release of the hold pin.
An error message is displayed for a shelf where cassette hold release fails.
This error occurs when the entire cassette hold release is not detected during the
above operation.
Sensor related
Error-related I/O locations
Error-related system block diagram
AC IN
CN5
DC OUT2
JPS-1
DC OUT3
009-051-04
05.31.99 FM2460
3
4
5
6
ON: Close, OFF: Open
SOLA1
SOLA2
SOLA3
SOLA4
SOLF1
SNS08A
CNA2
CN
CN6
CN13
CN4
DRV03D
CN3
CN2
CNA3
CN2
CN3
CN4
DRV08A
CN1
CR-IR341 Service Manual
SA3.7.11.15
Cassette hold sensor
Cassette hold solenoid
SOLA1—4 ON :SA3.7.11.15 OPEN
SOLA1—4 OFF :SA3.7.11.15 CLOSE
Cassette hold solenoid
SA3/7/11/15
CNSOLA1
SOLA1
SOLA2
CNSOLA2
SOLA3
CNSOLA3
SOLA4
CNSOLA4
FR1H0002.EPS
MT - 74
Hold pin
SOLA1—4
FR1H0001.EPS