8.10 Checking and Replacing Side-Positioning Top Stopper

Checks
(1) Remove the side-positioning conveyor.
"8.1 Removing and Reinstalling Side-Positioning Conveyor"
(2) Move the side-positioning mechanism to the right (small-size side) to raise the stopper.
(3) Make sure that the distance from the guide plate to the tip of the stopper is 6 ± 1 mm.
(4) Reinstall the side-positioning conveyor.
"8.1 Removing and Reinstalling Side-Positioning Conveyor"
009-051-04
05.31.99 FM2460
3
4
5
6
(1)
Side-positioning conveyor
CR-IR341 Service Manual
7
8
9
10
(2)
Stopper
Side view
(3)
6–1mm
Stopper
MC - 124
Side-positioning
mechanism
Guide
plate
FR1H1786.EPS
MC - 124