2.3.3 Locations to be First Checked When Trouble Occurs Immediately
After Startup
If an error (trouble) occurs during machine startup or during initial IP conveyance after
startup, check the priority checkpoints in accordance with the following table before
performing routine troubleshooting procedures.
Troubles during Machine Startup and their Corresponding Priority Checkpoints
(1/2)
Troubles
Not powered up (not activated by switches; no lamp
illumination or operation)
Stopped with "Could not initialize SCSI device"
displayed
Stopped with "VxWorks version 5.3" displayed
Bus error
CRT screen flicker
No CRT screen display
Shutdown process display (stopped at Step 99)
Cassette shelf error (13A3)
Shelf failure (shelf 1
2
Erasure lamp error (13AA)
Serious error
03C8
FANG1-3 not rotated
03BC
03BF
03C7
03C8
03C9
03DC
03DD
009-051-07
08.30.2001 FM3115
3
4
5
6
Power supply
(located on the left-hand side): CN4
MTH08A: CN22, CN25, CN27
HDD: CNJ1, CNJ2
SNS08A: CN4
Power supply
(located on the right-hand side): DCOUT2
MTH08A: CN19, CN20
SCN08A: CN7, CN9
SNS08A: CN1
Power supply
(located on the right-hand side): DCOUT6
CPU90E (VGA90E): CN7
CRT: CN2
CPU90E (VGA90E): CN19
CRT: CN1, CN4
LED08A: CN3
Power supply
(located on the right-hand side): DCOUT1
CPU90E: CN6
Power supply
(located on the left-hand side): CN3
Cassette set unit: SA3, 7, 11, 15
DRV08A: CN4
3
4
03A3)
Cassette set unit: CNA3
SCN08A: CN13
Power supply
(located on the left-hand side): CN5
Power supply
(located on the right-hand side): ACOUT1, 2
Subscanning unit: CN8, CN9
DRV08A: CN16
Side-positioning conveyor: SD1, CNMD1
DRV08A: CN1, CN12
SNS08A: CN9
Side-positioning conveyor: CNMD2, SD2,
Subscanning unit: CNZ2, CNZ6
Power supply
(located on the right-hand side): DCOUT3
Subscanning unit: CNMZ3
DRV08A: CN14
Subscanning unit: CNMZ2, SZ2
Subscanning unit: CNZ3, SZ3
DRV08A: CN15
After-reading conveyor: CNME1, SE1
Subscanning unit: CNZ10
DRV08A: CN6
SNS08A: CN6
Cassette set unit: SA17, CAN2
Up-down IP removal unit: CNMB3, CNB4
CR-IR341 Service Manual
Priority checkpoints
Connectors
LED08A: CN2
MTH08A: NFB4, NFB5
SNS08A: NFB1
Power supply fuse : F13
MTH08A: NFB2
Power supply fuse: F1
CPU90E: NFB2
CRT fuse
SOLA1-4
Power supply fuse: F10
DCOUT4
SNS08A: NFB2
CND1, CND2
Power supply fuse: F9, F12
Power supply fuse: F2
MT - 70