12.12 Checking, Replacing, and Adjusting Erasure Unit IP
Conveyance Timing Belt
Checks
If anything abnormal is found during checks, replace or adjust the erasure unit IP convey-
ance timing belt.
(1) Power OFF the machine.
(2) Remove the erasure conveyor.
"12.2 Removal and Reinstallation of Erasure Conveyor"
(3) Measure the tension value for the erasure unit IP conveyance timing belt.
With a load of 300 ± 50g applied, the deflection should be 11 ± 1mm.
Erasure conveyor
009-051-04
05.31.99 FM2460
13
14
15
16
CR-IR341 Service Manual
Timing belt
FRONT
Tensioner
300g ± 50g
11 ± 1mm
MF1
MC - 236
FR1H1188.EPS