C
1
2
ONTENTS
6.3
Checking and Replacing Convergence Standby IP Sensor
(SC2)
Checks
(1) Remove the SC2 and spacer with the connector attached.
(1)
SC2
Pan-head
M3x10, x2
(1)
Connector
(2) Place the machine in an SC2 monitoring enabled state.
"2.2 Checking Various Sensors"
(3) Using a cardboard or the like, block the SC2 light path.
A message indicating that the sensor is CLOSE appears on the operation panel.
(4) Remove the cardboard or the like that has blocked the SC2 light path.
A message indicating that the sensor is OPEN appears on the operation panel.
(5) Repeat steps (3) and (4) several times.
(6) Power OFF the machine.
(7) Reinstall the SC2.
009-051-04
05.31.99 FM2460
3
4
5
6
Before-side-
positioning
conveyor
(1)
Spacer
CR-IR341 Service Manual
7
8
9
10
FR1H1770.EPS
MC - 90
MC - 90