FujiFilm CR-IR341 Service Manual page 393

Fuji computed radiography
Table of Contents

Advertisement

1
2
C
ONTENTS
03D8 After-Reading Conveyance Remaining IP Ejection Error
Cause
During initialization, an IP is detected in the machine as a result of IP search, and it is
conveyed toward the inverting stocker, but SF2 does not turn OFF, Or, SF2 does not
turn ON, and SF4 transitions from ON to OFF.
Supplementary explanation
During initialization, each motor is activated, and each sensor is used to search for any
remaining IP left in the machine.
If any IP is detected in the machine, MF1 is driven to perform the IP ejection process.
The remaining IP detected is conveyed toward the inverting stocker of the erasure
conveyor, and the IP passes over SF2 and SF4 in this order.
After the IP passes over SF2 (SF2: ON to OFF), the driving of MF1 is stopped.
This error occurs when the IP does not completely pass over SF2 (SF2 status does
not transition from ON to OFF), or when the IP passes over SF4 (SF4: ON to OFF)
without being detected by SF2, during the above operation.
Sensor related
Error-related I/O locations
MF1 IP transport motor
SF4 Overrun IP sensor
SF2 Changeover IP sensor
SF1 After-reading conveyance
standby IP sensor
ME1 Grip release motor
Error-related system block diagram
AC IN
DC OUT2
JPS-1
DC OUT3
009-051-04
05.31.99 FM2460
3
4
5
6
ON: Close, OFF: Open
SNS08A
CN
CN13
CN4
DRV03D
CN3
CN3
DRV08A
CN1
CR-IR341 Service Manual
SOLA3
SOLA4
FR1H0085.EPS
CNF1
CNF2
MF1
CNMF1
FR1H0086.EPS