Fig. 4.2.2 Feed Step Operation (3/3)
The leading edge
of the IP fed by the
grip rollers is
detected. (The leading
edge of the IP shields
These steps
SB2.)
correspond to
"Feed
Conveyance"
described in
Fig. 2.4.4.
Table 4.2.2 Operation Parameters
Symbol
Description
PB11
Suction cup movement (HP
PB12
Suction cup movement (feed suction
PB18
Suction cup movement (feed leak
PB19
Suction cup movement (HP
PB21
Conveyance (feed suction synchronization)
PB26
Conveyance (grip retry)
NB11
Feed suction retry
TB11
Feed suction timeout
TB12
Wait for feed suction
TB13
Wait for feed leak
TB14
Grip timeout
TB17
Wait for next operation
TB18
Wait for feed
009-051-04
05.31.99 FM2460
3
4
5
6
B
Leak valve close
DRIVE (SVB1/OFF)
DELAY TB18
Is SB2 closed?
N
Y
Conveyance stop
DRIVE (MB2/OFF)
(soft)
END
Value
feed suction)
250 p
feed leak)
-262 p
load standby)
98 p
feed leak)
-12 p
675 p
+ infinite p
3 sec
1 sec
0 sec
0.1 sec
1 sec
0.1 sec
0.05 sec
TR1H0052.EPS
CR-IR341 Service Manual
7
8
9
10
Suction cup movement
(feed leak
DRIVE (MB1/PB18)
Conveyance driving
DRIVE (MB2/PB26)
Is SB2 closed within TB14?
Y
N
Conveyance stop
DRIVE (MB2/OFF) (soft)
(MB2 excitation OFF)
SB4 monitoring completed
DELAY TB17
Suction cup HP positioning
Fig. 2.3.2
Level 1 error
13E3
IP grip error
Error handling
Cassette ejection 2
Fig. 6.2.1
MD - 112
load standby)
FR1H0396.EPS
MD - 112