FujiFilm CR-IR341 Service Manual page 196

Fuji computed radiography
Table of Contents

Advertisement

C
1
2
ONTENTS
(14) Detailed Sequence of Movement of Before-Side-Positioning Conveyance Remaining IP
Fig. 5.3.14 Movement of Before-Side-Positioning Conveyance Remaining IP
Preprocessing: Fig. 5.3.1
Initialization
side-positioning
conveyance
Table 5.3.14 Operation Parameters
Symbol
PB71
Initialization conveyance (DOWN direction)
Initialization conveyance (DOWN direction)
PC71
Initialization conveyance (DOWN direction)
PD71
Side-positioning conveyance remaining IP ejection timeout 1
TD71
Initialization side-positioning timeout
TD75
009-051-04
05.31.99 FM2460
3
4
5
6
START
Side-positioning conveyance direction
DRIVE (MD3/PD71)
DRIVE (MC1/PC71)
DRIVE (MB1/PB71)
Is SC1 opened within TD71?
N
Y
Side-positioning conveyance direction stop
DRIVE (MD3/OFF) (soft)
DRIVE (MC1/OFF) (soft)
DRIVE (MB2/OFF) (soft)
Side-positioning conveyance direction
DRIVE (MD31/PD71)
Is SD3 closed within TD75?
N
Y
Side-positioning conveyance direction stop
DRIVE (MD31/OFF)
(soft)
Before-reading standby IP found
END
Description
CR-IR341 Service Manual
7
8
9
10
Side-positioning conveyance direction stop
DRIVE (MD3/OFF) (soft)
DRIVE (MC1/OFF) (soft)
DRIVE (MB2/OFF) (soft)
Level 0 error
03B7
Side-positioning conveyance
remaining IP ejection error
Side-positioning conveyance direction stop
DRIVE (MD31/OFF)
(soft)
Level 0 error
Side-positioning conveyance
03B7
remaining IP ejection error
Value
+ infinite p
+ infinite p
+ infinite p
7.6sec
5.8sec
TR1H0071.EPS
MD - 133
FR1H0418.EPS
MD - 133

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr-ir341pFcr 5000Fcr 5000plus

Table of Contents