show system hardware

Temp-Alarm
-------------
off
PS1-Type
-------------
6C207-1
Table
2‐5 provides an explanation of the command output.
Table 2-5 Show System Output Display
Output...
System contact
System location
System name
PS1 and PS2-Status
Fan Status
Temp-Alarm
Uptime d,h:m:s
Logout
PS1 and PS2-Type
show system hardware
Use this command to display the system's hardware configuration.
Syntax
show system hardware
Parameters
None.
Defaults
None.
Mode
Switch command, Read‐Only.
Uptime d,h:m:s
Logout
--------------
-------------
0,19:40:00
10 min
PS2-Type
-------------
not installed
What it displays...
Contact person for the system. Default of a blank string can be
changed with the set system contact command
on page 2-51).
Where the system is located. Default of a blank string can be changed
with the set system location command
page 2-50).
Name identifying the system. Default of a blank string can be changed
with the set system name command
page 2-50).
Operational status for power supply 1 and, if installed, power supply 2.
Operational status of the fan tray.
Whether or not the system temperature alarm is off (within normal
temperature range) or on.
System uptime.
Time an idle console or Telnet CLI session will remain connected
before timing out. Default of 15 minutes can be changed with the set
logout command
Model number of power supply 1 and, if installed, power supply 2.
("set system
("set system
("set
logout" on page 2-53).
Enterasys Matrix DFE-Gold Series Configuration Guide 2-35
Setting Basic Device Properties
("set system
contact"
location" on
name" on

Hide quick links: