Enterasys Discovery Protocol
A device with the default authentication code (16 null characters) will recognize all devices, no
matter what their authentication code, and enter them into its CDP neighbor table.
Example
This example shows how to set the CDP authentication code to 1,2,3,4,5,6,7,8:
Matrix(rw)->set cdp auth 1,2,3,4,5,6,7,8
set cdp interval
Use this command to set the message interval frequency (in seconds) of the CDP discovery
protocol.
Syntax
set cdp interval frequency
Parameters
frequency
Defaults
None.
Mode
Switch command, Read‐Write.
Example
This example shows how to set the CDP interval frequency to 15 seconds:
Matrix(rw)->set cdp interval 15
set cdp hold-time
Use this command to set the hold time value for CDP discovery protocol configuration messages.
Syntax
set cdp hold-time hold-time
Parameters
hold‐time
Defaults
None.
Mode
Switch command, Read‐Write.
3-6 Discovery Protocols Configuration
Specifies the transmit frequency of CDP messages in seconds.Valid
values are from 5 to 900 seconds.
Specifies the hold time value for CDP messages in seconds.Valid values
are from 15 to 600.
set cdp interval