Set Flowlimit Limit - Enterasys Matrix DFE-Gold Series Configuration Manual

Enterasys networks switch configuration guide
Table of Contents

Advertisement

set flowlimit limit

Example
This example shows how to enable FST on Fast Ethernet ports 1‐5 in module 2:
Matrix(rw)->set flowlimit fe.2.1-5 enable
set flowlimit limit
Use this command to set a flow limit that will trigger an action for a port user classification.
Syntax
set flowlimit {limit1 | limit2 limit} [userport | serverport | aggregateduser |
interswitchlink | unspecified]
Parameters
limit1 | limit2
limit
userport | serverport 
| aggregateduser | 
interswitchlink | 
unspecified 
Defaults
If classification port type is not specified, none will be applied. 
Mode
Switch command, Read‐Write.
Usage
Once configured, this limit can be associated with an action using the set flowlimit action 
command as described in "set flowlimit action" on page 24‐28. This limit can be assigned to one or 
more ports using the set flowlimit class command as described in "set flowlimit port" on 
page 24‐31.
Example
This example shows how to set the flow limit 1 to 12 flows on ports classified as user ports: 
Matrix(rw)->set flowlimit limit1 12 userport
Specifies this configuration as limit 1 or 2. Two limits assigned to two 
actions (describing what will occur when a certain flow limit is reached) 
can be defined per user classification. 
Specifies the number of flows that will trigger the associated action 
configuration. Valid values are 0 ‐ 4294967295.
(Optional) Assigns this limit configuration to the user classification port 
type:
user port 
server port
aggregation port
inter‐switch link
unspecified port
Enterasys Matrix DFE-Gold Series Configuration Guide 24-27
Configuring Flow Setup Throttling (FST)

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents