Clear Inlinepower Available - Enterasys Matrix DFE-Gold Series Configuration Manual

Enterasys networks switch configuration guide
Table of Contents

Advertisement

Configuring Power over Ethernet (PoE)
Parameters
max-
percentage
Defaults
None.
Mode
Switch command, Read‐Write.
Usage
If the total power wattage value set with the set inlinepower assigned command ("set 
inlinepower assigned" on page 2‐66) is greater that the maximum power percentage specified 
with this command, a warning will display. If the user opts to execute these parameters, a ratio of 
assigned power will be applied to each module. Refer to the show inlinepower output ("show 
inlinepower" on page 2‐61) for a sample warning message.
Example
This example shows how to set the maximum inline power available to the chassis to 70 percent:
Matrix(rw)->set inlinepower available 70

clear inlinepower available

Use this command to reset the percentage of the total power available to a chassis to the default 
value of 100.
Syntax
clear inlinepower available
Parameters
None.
Defaults
None.
Mode
Switch command, Read‐Write.
Example
This example shows how to reset the maximum inline power available to the chassis to 100 
percent:
Matrix(rw)->clear inlinepower available
2-64 Startup and General Configuration
Specifies the percentage of maximum power available. Valid values are 
0 ‐ 100.
clear inlinepower available