Setting Basic Device Properties
Mode
Switch command, Read‐Write.
Usage
These settings will start and stop daylight savings time at the specified day of the month and hour
each year and will not have to be reset annually.
Example
This example shows how set daylight savings time to recur start date of April 4, 2004 at 2 a.m. and
an ending date of October 31, 2004 at 2 a.m. with an offset time of one hour:
Matrix(rw)->set summertime recurring first Sunday April 02:00 last Sunday October
02:00 60
clear summertime
Use this command to clear the daylight savings time configuration.
Syntax
clear summertime
Parameters
None.
Defaults
None.
Mode
Switch command, Read‐Write.
Example
This example shows how to clear the daylight savings time configuration:
Matrix(rw)->clear summertime
set prompt
Use this command to modify the command prompt.
Syntax
set prompt "prompt_string"
Parameters
prompt_string
2-44 Startup and General Configuration
Specifies a text string for the command prompt.
Note: A prompt string containing a space in the text must be enclosed in quotes
as shown in the example below.
clear summertime