set flowlimit notification
Parameters
enable | disable
Defaults
None.
Mode
Switch command, Read‐Write.
Usage
When enabled, this allows ports configured with a "trap" action to send an SNMP trap message
when a specified flow limit is reached.
When enabled, this allows ports configured with a "disable" action to shut down. For information
on using the set flowlimit limit command to configure set a disable action on a port, refer to "set
flowlimit limit" on page 24‐27.
Example
This example shows how to enable the flow limit shut down function:
Matrix(rw)->set flowlimit shutdown enable
set flowlimit notification
Use this command to enable or disable flow limit notification, or to set a notification interval.
Syntax
set flowlimit notification {disable | enable | interval}
Parameters
disable | enable
interval
Defaults
None.
Mode
Switch command, Read‐Write.
Example
This example shows how to enable the flow limit notification function:
Matrix(rw)->set flowlimit notification enable
Enables or disables the flow limit shut down function.
Disables or enables SNMP notification.
Specifies a notification interval (in seconds) for SNMP trap messages.
Valid values are 0 ‐ 4294967295.
Enterasys Matrix DFE-Gold Series Configuration Guide 24-33
Configuring Flow Setup Throttling (FST)