set rmon alarm properties

Sample Type
Interval
Rising Threshold
Rising Event Index
Table
11‐4 provides an explanation of the command output.
Table 11-4 show rmon alarm Output Details
Output...
Index
Owner
Status
Variable
Sample Type
Startup Alarm
Interval
Rising Threshold
Falling Threshold
Rising Event Index
Falling Event Index
set rmon alarm properties
Use this command to configure an RMON alarm entry, or to create a new alarm entry with an 
unused alarm index number. 
Syntax
set rmon alarm properties index [interval interval] [object object] [type
{absolute | delta}] [startup {rising | falling | either}] [rthresh rthresh]
[fthresh fthresh] [revent revent] [fevent fevent] [owner owner]
Parameters
index
interval interval
object object
type absolute | delta
= delta
Startup Alarm
= 30
Value
= 1
Falling Threshold
= 2
Falling Event Index = 0
What it displays...
Index number for this alarm entry.
Text string identifying who configured this entry.
Whether this event entry is enabled (valid) or disabled.
MIB object to be monitored.
Whether the monitoring method is an absolute or a delta sampling.
Whether alarm generated when this entry is first enabled is rising,
falling, or either.
Interval in seconds at which RMON will conduct sample monitoring.
Minimum threshold for causing a rising alarm.
Maximum threshold for causing a falling alarm.
Index number of the RMON event to be triggered when the rising
threshold is crossed.
Index number of the RMON event to be triggered when the falling
threshold is crossed.
Specifies an index number for this entry. Maximum number or entries is 
50. Maximum value is 65535.
(Optional) Specifies an interval (in seconds) for RMON to conduct 
sample monitoring. 
(Optional) Specifies a MIB object to be monitored.
Note: This parameter is not mandatory for executing the command, but must be
specified in order to enable the alarm entry configuration.
(Optional) Specifies the monitoring method as: sampling the absolute 
value of the object, or the difference (delta) between object samples.
Enterasys Matrix DFE-Gold Series Configuration Guide 11-21
Configuring RMON
= rising
= 0
= 0