set radius accounting
Defaults
If no parameters are specified, all RADIUS accounting configuration information will be
displayed.
Mode
Switch command, Read‐Only.
Example
This example shows how to display RADIUS accounting configuration information. In this case,
RADIUS accounting is enabled and global default settings have not been changed. One server has
been configured. The Enterasys Matrix Series device allows for up to 10 RADIUS accounting
servers to be configured, with up to 2 active at any given time.
For details on enabling and configuring RADIUS accounting, refer to "set radius accounting" on
page 25‐57:
Matrix(rw)->show radius accounting
Accounting state:
Accounting update interval:
Accounting interval minimum:
Server
Index
-----------------------------------------------------------------
1
set radius accounting
Use this command to configure RADIUS accounting.
Syntax
set radius accounting {[enable] [disable] [intervalminimum value] [updateinterval
value] [retries retries] [timeout timeout] [server {index | all} ip_address port
[server-secret]
Parameters
enable | disable
intervalminimum
value
updateinterval value
retries retries
timeout timeout
Enabled
1800 secs
600 secs
Server
Acct
IP
Port
1.1.1.1
1236
Enables or disables the RADIUS accounting client.
Sets the minimum interval at which RADIUS accounting will send
interim updates. Valid values are 60 ‐ 2147483647.
Sets the number of seconds between each RADIUS accounting interim
update (when accumulated accounting data is sent to the server for a
session.) Valid values are 180 ‐ 2147483647.
Sets the maximum number of attempts to contact a specified RADIUS
accounting server before timing out. Valid retry values are 1 ‐
2147483647.
Sets the maximum amount of time (in seconds) to establish contact with
a specified RADIUS accounting server before timing out. Valid timeout
values are 1 ‐ 2147483647.
Retries
Timeout
2
5
Enterasys Matrix DFE-Gold Series Configuration Guide 25-57
Configuring RADIUS
Status
Primary
Need help?
Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?
Questions and answers