Configuring Power over Ethernet (PoE)
set inlinepower assigned
Use this command to manually assign Power Sourcing Equipment (PSE) power to a module in the
chassis.
Syntax
set inlinepower assigned power-value slot-number
Parameters
power‐value
slot‐number
Defaults
None.
Mode
Switch command, Read‐Write.
Usage
If the total power wattage value set with this command is greater that the maximum power
percentage specified with the set inlinepower available command ("set inlinepower available" on
page 2‐63), a warning will display. If the user opts to execute these parameters, a ratio of assigned
power will be applied to each module. Refer to the show inlinepower output ("show
inlinepower" on page 2‐61) for a sample warning message.
Example
This example shows how to assign 200 watts of power to the module in slot 1:
Matrix(rw)->set inlinepower assigned 200 1
clear inlinepower assigned
Use this command to clear the power value manually assigned to one or more modules.
Syntax
clear inlinepower assigned [slot-number]
Parameters
slot‐number
Defaults
If slot‐number is not specified, power value assignments will be cleared from all modules.
Mode
Switch command, Read‐Write.
2-66 Startup and General Configuration
Specifies a power value in watts.
Specifies a module slot location for the power assignment.
(Optional) Clears the power assignment from a specific module.
set inlinepower assigned
Need help?
Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?