Set Rmon Alarm Status - Enterasys Matrix DFE-Gold Series Configuration Manual

Enterasys networks switch configuration guide
Table of Contents

Advertisement

Configuring RMON
startup rising | 
falling | either
rthresh rthresh
fthresh fthresh
revent revent
fevent fevent
owner owner
Defaults
interval ‐ 3600 seconds
type ‐ absolute
startup ‐ rising
rthresh ‐ 0
fthresh ‐ 0
revent ‐ 0
fevent ‐ 0
owner ‐ monitor
Mode
Switch command, Read‐Write.
Example
This example shows how to configure a rising RMON alarm. This entry will conduct monitoring 
of the delta between samples every 30 seconds:
Matrix(rw)->set rmon alarm properties 3 interval 30 object
1.3.6.1.4.1.5624.1.2.29.1.2.1.0 type delta rthresh 1 revent 2 owner Manager

set rmon alarm status

Use this command to enable an RMON alarm entry. 
Syntax
set rmon alarm status index enable
11-22 Network Monitoring Configuration
(Optional) Specifies the type of alarm generated when this event is first 
enabled as:
Rising ‐ Sends alarm when an RMON event reaches a maximum 
threshold condition is reached, for example, more than 30 collisions 
per second.
Falling ‐ Sends alarm when RMON event falls below a minimum 
threshold condition, for example when the network is behaving 
normally again.
Either ‐ Sends alarm when either a rising or falling threshold is 
reached.
(Optional) Specifies a minimum threshold for causing a rising alarm. 
(Optional) Specifies a maximum threshold for causing a falling alarm.
(Optional) Specifies the index number of the RMON event to be 
triggered when the rising threshold is crossed.
(Optional) Specifies the index number of the RMON event to be 
triggered when the falling threshold is crossed.
(Optional) Specifies the name of the entity that configured this alarm 
entry.
set rmon alarm status