Clear Spantree Lpthreshold; Set Spantree Lpwindow - Enterasys Matrix DFE-Gold Series Configuration Manual

Enterasys networks switch configuration guide
Table of Contents

Advertisement

Configuring Spanning Tree Loop Protect Features
Example
This example shows how to display the current Loop Protect threshold value:
Matrix(rw)->show spantree lpthreshold
LoopProtect event threshold is set to 4

clear spantree lpthreshold

Use this command to return the Loop Protect event threshold to its default value of 3.
Syntax
clear spantree lpthreshold
Parameters
None.
Defaults
None.
Mode
Switch command, Read‐Write.
Example
This example shows how to reset the Loop Protect event threshold to the default of 3:
Matrix(rw)->clear spantree lpthreshold

set spantree lpwindow

Use this command to set the Loop Protect event window value in seconds.
Syntax
set spantree lpwindow value
Parameters
value
Defaults
None. 
Mode
Switch command, Read‐Write.
Usage
The Loop Protect Window is a timer value, in seconds, that defines a period during which Loop 
Protect events are counted. The default value is 180 seconds. If the timer is set to 0, the event 
6-72 Spanning Tree Configuration
Specifies the number of seconds that comprise the period during which 
Loop Protect events are counted. The default event window is 180 
seconds.
clear spantree lpthreshold