How to Use This Guide

Use this guide to quickly set up your Enterasys® SecureStack B‐Series switch. Enterasys Networks recommends that you refer to the Enterasys SecureStack B‐Series Hardware Installation Guide associated with your switch for specifications and safety warnings.

The latest documentation is located at www.enterasys.com/support/manuals.

Hardware Components

The following figures show the several types of front panel port and rear panel connections on your B‐Series switch.

Hardware Components

Key

  1. Switch Status LEDs
  2. RJ45 Ports
  3. SFP Ports
  4. Combo SFP Ports
  5. DB9 RS232 Console Port Connector
  6. SFP Port Status LEDs
  7. RJ45 Port Status LEDs
  8. Stack Connection Ports
  9. Password Reset Button
  10. AC Power Input Connector
  11. Redundant Power Supply (RPS) DC Connector

Handling the Switch


The switch can be damaged by electrostatic discharge.

To prevent electrostatic damage, attach an electrostatic discharge (ESD) wrist strap to your wrist before handling the switch.

Unpacking the Switch

Unpack the switch as follows:

  1. Remove the packing material protecting the switch.
  2. Remove the tape seal on the non‐conductive bag to remove the switch.
  3. Perform a visual inspection of the switch for any signs of physical damage. Contact Enterasys Networks if there are any signs of damage. See "Getting Help" for more information on contacting Enterasys Networks.

Connecting Power to the Switch

shock hazard Electrical Hazard: Only qualified personnel should perform installation procedures.

Note: Enterasys Networks recommends installing any components before powering on your switch.

You can connect to a single, primary source of power, or to two sources of power for redundancy.

The following redundant power supplies are available to be purchased from Enterasys Networks:

  • C2RPS‐PSM, a 150 watt DC power supply capable of providing power to a fully‐loaded non‐PoE switch.
  • C2RPS‐POE (B2H124‐48P, B3G124‐24P, and B3G124‐48P only), 500 watt DC power supply for PoE switches.

To power‐up your B‐Series switch:

  1. If you are connecting a redundant power supply, attach the C2RPS‐PSM cable (for not PoE) or C2RPS‐POE cable (for PoE) from your redundant power supply to the A2 switch's redundant power connector.
  2. Attach the AC power cord to the B‐Series switch's AC power receptacle.
  3. Plug the redundant power supply (if applicable) and the B‐Series switch AC power cord into dedicated, grounded AC outlets.
    Note: To take full advantage of redundancy, each power supply should be plugged-in to a separate dedicated AC outlet.
  4. Once power is connected, verify the RPS power LED turns green, and CPU (system) LED turns amber until the B‐Series switch finishes its initialization.
  5. If the initialization process is successful, the CPU LED turns green. If the CPU LED does not turn green, refer to the Enterasys SecureStack B‐Series Hardware Installation Guide associated with your B‐Series switch for troubleshooting information.

Completing Switch Setup and Downloading the Latest Firmware

Once you have connected power to the B‐Series switch and verified LED activity, you can complete the setup process as follows. Refer to the Enterasys SecureStack B‐Series Hardware Installation Guide associated with your B‐Series switch for more information.

  1. Determine the latest B‐Series firmware version by visiting the Enterasys Networks download site at: http://secure.enterasys.com/services/support/downloads/software
  2. Connect the switch to the network.
  3. Connect a management station to the console port.
  4. Verify that the network devices connected to the switch ports are powered on, and that each link/activity LED is on (solid green or blinking green).
  5. At the device connected to the console port, perform the following:
    1. Enter admin for Username.
    2. At the Password prompt, press ENTER (RETURN).
    3. At the command prompt, determine if the latest firmware image is loaded on the switch by entering this command:
      show version
    4. If the output (under FW Version) displays an older version number than that determined in Step 1, download and activate the new version as directed on the download website. (Alternatively, you can use the CLI command listed in Table 1.)

Basic Setup Commands

Table 1 lists CLI commands that are required for setting up the B‐Series switch with the latest firmware. Table 2 lists additional configuration commands for your B‐Series switch. For the complete list of CLI commands, see the Enterasys SecureStack C3 Configuration Guide.

Table 1 Required CLI Setup Commands

Step Task CLI commands
1 Set a new password set password [username]
2 Set the switch IP address set ip address ip-address [mask ip-mask] [gateway ip-gateway]
3

Download, activate, and verify new firmware on the switch using TFTP copy

Note: You can reboot the system immediately with the set boot system command, or reboot later with the reset command.

copy
tftp://
tftp_server_ip_address/filename system: image
set boot system filename
show version

Table 2 Optional CLI Setup Commands

Task CLI commands
Save the active configuration save config
Enable or disable SSH set ssh enable | disable
Enable or disable Telnet set telnet {enable | disable} [inbound | outbound | all]
Enable or disable HTTP management (WebView) set webview {enable | disable}
Enable or disable SNMP port link traps set port trap port-string {enable | disable}
Set the per port broadcast limit set port broadcast port-string threshold-value
Configure a VLAN set vlan create vlan-id set port vlan port-string vlan-id modify-egress
Set a Syslog server IP and severity set logging server index ip-addr ip-addr severity severity state enable
Configure and enable a RADIUS server set radius server index ip-addr port [secret-value] {realm {management-access | any | network-access}
set radius enable

Specifications

For a complete list of specifications, see the Enterasys SecureStack B‐Series Hardware Installation Guide associated with your B‐Series switch.

Interfaces

Note: The RJ45 ports on the B2H124-48P, B3G124-24P, and the B3G124-48P also support 802.af PoE connections.

B2H124‐48 and B2H124‐48P

  • Four SFP ports that support 1000BASE‐LX, 1000BASE‐SX, or 1000BASE‐T connections
  • Forty‐eight 10BASE‐T/100BASE‐TX RJ45 ports

B3G124‐24 and B3G124‐24P

  • Four combo SFP ports that support 1000BASE‐LX, 1000BASE‐SX, or 1000BASE‐T connections
  • Twenty‐four 10BASE‐T/100BASE‐TX/1000BASE‐T RJ45 ports

B3G124‐48 and B3G124‐48P

  • Four combo SFP ports that support 1000BASE‐LX, 1000BASE‐SX, or 1000BASE‐T connections
  • Forty‐eight 10BASE‐T/100BASE‐TX/1000BASE‐T RJ45 ports

Switch Dimensions

Size: 354.40 x 441 x 44.0 mm

Power Consumption

Input Voltage: 100 to 240VAC

Temperature and Humidity

Operating: 0ºC to 50ºC

Storage: ‐40ºC to +70ºC

Getting Help

World Wide Web www.enterasys.com/services/support/
Phone

1-800-872-8440 (toll-free in U.S. and Canada) or 1-978-684-1000

To find the Enterasys Networks Support toll-free number in your country: www.enterasys.com/services/support/contact/

Internet mail

support@enterasys.com

To expedite your message, type [Switching] in the subject field of your message.

Latest image and release notes www.enterasys.com/services/support/downloads/software/

The latest B‐Series documentation is located online at: www.enterasys.com/support/manuals

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Enterasys B2H124-48/48P, B3G124-24/24P, B3G12448/48P Quick Reference Guide

Advertisement

Need Assistance?

Do you have a question about the B2H124-48 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents