show spantree lpwindow

counter is not reset until the Loop Protect event threshold is reached. If the threshold is reached, 
that constitutes a loop protection event.
Example
This example shows how to set the Loop Protect event window to 120 seconds:
Matrix(rw)->set spantree lpwindow 120
show spantree lpwindow
Use this command to display the current Loop Protect event window value.
Syntax
show spantree lpwindow
Parameters
None.
Defaults
None. 
Mode
Switch command, Read‐Only.
Example
This example shows how to display the current Loop Protect window value:
Matrix(rw)->show spantree lpwindow
LoopProtect event window is set to 120 seconds

clear spantree lpwindow

Use this command to reset the Loop Protect event window to the default value of 180 seconds.
Syntax
clear spantree lpwindow
Parameters
None.
Defaults
None.
Mode
Switch command, Read‐Write.