Set Rmon Alarm Status - Enterasys SecureStack C2 Configuration Manual

Stackable switches
Hide thumbs Also See for SecureStack C2:
Table of Contents

Advertisement

set rmon alarm status

Defaults
interval ‐ 3600 seconds
type ‐ absolute
startup ‐ rising
rthresh ‐ 0
fthresh ‐ 0
revent ‐ 0
fevent ‐ 0
owner ‐ monitor
Mode
Switch command, read‐write.
Example
This example shows how to configure a rising RMON alarm. This entry will conduct monitoring 
of the delta between samples every 30 seconds:
C2(rw)->set rmon alarm properties 3 interval 30 object
1.3.6.1.4.1.5624.1.2.29.1.2.1.0 type delta rthresh 1 revent 2 owner Manager
set rmon alarm status
Use this command to enable an RMON alarm entry. An alarm is a notification that a statistical 
sample of a monitored variable has crossed a configured threshold. 
Syntax
set rmon alarm status index enable
Parameters
index
enable
Defaults
None.
Mode
Switch command, read‐write.
Usage
An RMON alarm entry can be created using this command, configured using the set rmon alarm 
properties command ("set rmon alarm properties" on page 13‐9), then enabled using this 
command. An RMON alarm entry can be created and configured at the same time by specifying 
an unused index with the set rmon alarm properties command.
13-10 RMON Configuration
Specifies an index number for this entry. Maximum number or entries is 
50. Maximum value is 65535.
Enables this alarm entry.

Advertisement

Table of Contents
loading

Table of Contents