Oam Retry - ADTRAN AOS Version R10.1.0 Command Reference Manual

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide

oam retry

Use the oam retry command to configure parameters related to operations, administration, and
maintenance (OAM) management for an asynchronous transfer mode (ATM) interface. Use the no form of
this command to disable OAM management parameters. Variations of this command include:
oam retry
oam retry <up value>
oam retry <up value> <down value>
oam retry <up value> <down value> <value>
Syntax Description
<up value>
<down value>
<value>
Default Values
By default, the up-count is set to 3, the down-count is set to 5, and the retry frequency is 1.
Command History
Release 8.1
Usage Examples
The following example configures the OAM parameters with an up-count of 2, down-count of 2, and retry
frequency of 10:
(config)#interface atm 1.1
(config-atm 1.1)#oam retry 2 2 10
60000CRG0-35E
Optional. Specifies the number of consecutive end-to-end F5 OAM
loopback cell responses that must be received in order to change a
permanent virtual circuit (PVC) connection state to up. Range is 1 to 255.
Optional. Specifies the number of consecutive end-to-end F5 OAM
loopback cell responses that are not received in order to change a PVC
state to down. Range is 1 to 255.
Optional. Specifies the frequency (in seconds) that end-to-end F5 OAM
loopback cells are transmitted when a change in the up/down state of a
PVC is being verified. Range is 1 to 600 seconds.
Command was introduced.