Command Reference Guide
clock source
Use the clock source command to configure the source timing used for the interface. The clock specified
using the clock source command is also the system master clock. Use the no form of this command to
return to the default value. Variations of this command include:
clock source local
clock source loop
Syntax Description
local
loop
Default Values
By default, all T3 interfaces are configured with loop as the clock source.
Command History
Release 6.1
Usage Examples
The following example configures the unit to recover clocking from the circuit:
(config)#interface t3 1/1
(config-t3 1/1)#clock source loop
60000CRG0-35E
Configures the unit to provide clocking using the internal oscillator.
Configures the unit to recover clocking from the T3 circuit.
Command was introduced.
Copyright © 2012 ADTRAN, Inc.
T3 Interface Command Set
1933
Need help?
Do you have a question about the AOS Version R10.1.0 and is the answer not in the manual?