ADTRAN AOS Version R10.1.0 Command Reference Manual page 1923

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide
remote-alarm rai
The remote-alarm rai command selects the alarm signaling type to be sent when a loss of frame is
detected on the T1 receive signal. Use the no form of this command to disable all transmitted alarms.
Syntax Description
rai
Default Values
The default for this command is rai.
Command History
Release 7.1
Usage Examples
The following example enables transmission of RAI in response to a loss of frame:
(config)#interface t1 1/1
(config-t1 1/1)#remote-alarm rai
60000CRG0-35E
Specifies sending a remote alarm indication (RAI) in response to a loss of
frame. Also, prevents a received RAI from causing a change in interface
operational status.
Command was expanded to include the T1 interface.
Copyright © 2012 ADTRAN, Inc.
T1 Interface Command Set
1923