Figure 15.13 Sample Multiprocessor Serial Reception Flowchart (1) - Renesas H8S Series Hardware Manual

16-bit single-chip microcomputer
Hide thumbs Also See for H8S Series:
Table of Contents

Advertisement

Section 15 Serial Communication Interface (SCI, IrDA)
Set MPIE bit in SCR to 1
Read ORER and FER flags in SSR
FER ∨ ORER = 1
Read RDRF flag in SSR
No
Read receive data in RDR
No
This station's ID?
Read ORER and FER flags in SSR
FER ∨ ORER = 1
Read RDRF flag in SSR
Read receive data in RDR
No
All data received?
Clear RE bit in SCR to 0

Figure 15.13 Sample Multiprocessor Serial Reception Flowchart (1)

Rev. 3.00 Jul. 14, 2005 Page 470 of 986
REJ09B0098-0300
Initialization
Start reception
No
RDRF = 1
Yes
Yes
Yes
No
RDRF = 1
Yes
Yes
<End>
[1] SCI initialization:
[1]
The RxD pin is automatically designated
as the receive data input pin.
[2] ID reception cycle:
Set the MPIE bit in SCR to 1.
[2]
[3] SCI status check, ID reception and
comparison:
Read SSR and check that the RDRF
Yes
flag is set to 1, then read the receive
data in RDR and compare it with this
station's ID.
If the data is not this station's ID, set the
MPIE bit to 1 again, and clear the RDRF
[3]
flag to 0.
If the data is this station's ID, clear the
RDRF flag to 0.
[4] SCI status check and data reception:
Read SSR and check that the RDRF
flag is set to 1, then read the data in
RDR.
[5] Receive error processing and break
detection:
If a receive error occurs, read the ORER
and FER flags in SSR to identify the
error. After performing the appropriate
error processing, ensure that the ORER
and FER flags are all cleared to 0.
Reception cannot be resumed if either
of these flags is set to 1.
In the case of a framing error, a break
can be detected by reading the RxD pin
[4]
value.
No
Legend
∨ : Logical add (OR)
[5]
Error processing
(Continued on
next page)