Section 15 Serial Communication Interface (SCI, IrDA)
(2)
Reception
During reception, IR frames are converted to UART frames using the IrDA interface before
inputting to SCI_1. Here, the input waveform can also be inverted using the IrRxINV bit in
SCICR.
Data of level 0 is output each time a high-level pulse is detected and data of level 1 is output when
no pulse is detected in a bit cycle. If a pulse has a high-level width of less than 1.41 µs, the
minimum width allowed, the pulse is recognized as level 0.
Rev. 3.00 Jul. 14, 2005 Page 494 of 986