• Flash multipurpose address area (FMPAR)
• Flash multipurpose data destination area (FMPDR)
• Flash erase block select (FEBS)
• Flash programming/erasing frequency control (FPEFEQ)
There are several operating modes for accessing flash memory, for example, read mode/program
mode.
There are two memory MATs: user MAT and user boot MAT. The dedicated registers/parameters
are allocated for each operating mode and MAT selection. The correspondence between operating
modes and registers/parameters for use is shown in table 21.3.

Table 21.3 Register/Parameter and Target Mode

Programming/
FCCS
erasing interface
FPCS
registers
FECS
FKEY
FMATS
FTDAR
Programming/
DPFR
erasing interface
FPFR
parameters
FPEFEQ
FMPAR
FMPDR
FEBS
Notes: 1. The setting is required when programming or erasing the user MAT in user boot mode.
2. The setting may be required according to the combination of initiation mode and read
target MAT.
Section 21 Flash Memory (0.18-µm F-ZTAT Version)
Download Initialization
Ο
Ο
Ο
Ο
Ο
Ο
Ο
Ο
Programming
Erasure
Ο
Ο
Ο*
Ο*
1
1
Ο
Ο
Ο
Ο
Ο
Rev. 3.00 Jul. 14, 2005 Page 745 of 986
Read
Ο*
2
REJ09B0098-0300