Section 15 Serial Communication Interface (SCI, IrDA)
nth transfer frame
Ds
D0 D1 D2 D3 D4 D5 D6 D7 Dp DE
TDRE
Transfer from TDR to TSR
TEND
FER/ERS
Figure 15.26 Data Re-transfer Operation in SCI Transmission Mode
Note that the TEND flag is set in different timings depending on the GM bit setting in SMR,
which is shown in figure 15.27.
I/O data
TXI
(TEND interrupt)
GM = 0
GM = 1
[Legend]
Ds:
Start bit
D0 to D7: Data bits
Dp:
Parity bit
DE:
Error signal
etu:
Element Time Unit (time taken to transfer one bit)
Figure 15.27 TEND Flag Set Timings during Transmission
Rev. 3.00 Jul. 14, 2005 Page 486 of 986
REJ09B0098-0300
Ds D0 D1 D2 D3 D4 D5 D6 D7 Dp
Transfer from TDR to TSR
[2]
[1]
Ds
D0
D1
D2
D3
11.0 etu
Retransfer frame
(DE)
D4
D5
D6
D7
Dp
12.5 etu
(n + 1) th
transfer frame
Ds D0 D1 D2 D3 D4
Transfer from TDR to TSR
[3]
[3]
DE
Guard time